3 Phase On Line UPS
10 series (6KVA~20KVA)

Rated Capacity

Vertical type: 6KVA~20KVA

Scope Of Application

  • Information/network/communication room
  • High-tech electronics factory
  • Medical equipment
  • SMT automation equipment
  • Fire program control equipment
  • Telecom Workstation/Satellite Transmitting Station
  • Model UPS FT10-15U UPS FT10-20U
    Rated capacity 6KVA 10KVA 15KVA 20KVA
    The efficiency of the whole machine 89%, On-line online double conversion
    Enter Voltage and range 220V or 380V (three-phase three-wire)
    Voltage and range 50Hz or 60Hz (automatic detection); ±4Hz
    Work factor improvement ≧0.99 @ 100% load, to avoid interference with the operation of other instruments
    Output Rated voltage and frequency 220V or 380V(three-phase three-wire)
    190/110V or 208/120V or 380/220V(three-phase four-wire), and can be specially designed according to requirements; 50Hz or 60Hz
    Stability rated voltage ± 1%; rated frequency ± 0.2Hz
    Waveform/Crest Ratio Pure sine wave/3:1
    Power factor 0.8 (optional 0.9 model)
    Harmonic distortion ≦ 2% @ under linear load; ≦ 5% @ under non-linear load
    Conversion time Zero conversion
    Battery Type Lead-acid, water-free and maintenance-free closed type
    Discharge method Configure the battery pack according to customer needs to meet the discharge time
    Charging method Using a smart microcomputer to control two-stage charging to extend battery life and recharge more than 90% of the power within eight hours
    Panel test The battery self-test can be performed directly through the LCD panel
    Protection circuit With battery short-circuit, over-charging and discharging, and battery overheating protection
    Operation tips LED lights With bypass power supply, UPS operation, battery power supply and UPS fault lights
    LCD panel With UPS status and operation instructions, including input/output: voltage/current/frequency/actual power/apparent power
    load: capacity/percentage, battery: voltage/current/capacity and UPS fault display records (up to 4000 records)
    Communication interface Standard configuration RS-232/ USB/Smart card slot
    Optional The smart card slot can be installed: RS-232/USB/SNMP/AS-400/ModBus, etc.
    Machine function Modularization The whole machine adopts modular design, which has achieved the purpose of quick maintenance and convenient replacement
    Cold boot It can be powered on by internal battery energy when there is no mains power
    Hot redundant aid parallel connection Hot redundant parallel connection function, which can be expanded and used in the future. In addition, when two (above) machines are connected in parallel, they will automatically share current and output to the load; as long as any UPS fails, the normal host will automatically connect and supply all loads, without the problem of back-end load interruption. Up to four units can be connected in parallel (optional)
    EPO latch Equipped with EPO emergency disconnect pin, you can install a switch by yourself. When the machine is abnormal, the output can be quickly interrupted
    Overload capacity 101%~110% for one hour; 111%~125% for ten minutes; 126%~150% for one minute; more than 151% immediately switch to Bypass. After the overload condition disappears, the system will automatically switch back to the inverter power supply mode.
    Alarm sounds Battery power supply, low battery voltage, overload and UPS failure
    Smart fan Intelligent control fan, according to the load and ambient temperature, automatically adjust the fan speed, in order to achieve the purpose of saving power and reducing noise
    Isolation module You can choose to install isolation modules to improve the problem of poor mains grounding
    ECO mode Provide ECO power saving mode, increase the efficiency to 98%, and achieve the purpose of energy saving and power saving
    Other functions With non-interrupted manual maintenance bypass function. UPS can be repaired without interrupting the back-end load
    Web/SNMP management interface Add SNMP network management card to remotely manage UPS
    Monitoring software Support Win 2000/XP/Vista/7/8/10, Win Server 2000/2008/2012/2016, Linux, Unix and Mac systems
    Safety certification With the Commodity Verification Registration Certificate (BSMI) of the Bureau of Standards, Metrology and Inspection of the Ministry of Economic Affairs, CNS14843-1 (93 version) and CNS14757-2 (99 version)
    Noise (distance one meter) ≦58dBA ≦60dBA
    Using environment Temperature/Humidity 0℃~40℃; 0%~90% (non-condensing)
    Size• length x width x height (mm) 660  x250 x826
    Weight (kg) 109 164

    *If there is any change to this product, a specification confirmation will be attached separately.