N+X Modular Stacked UPS System
KP series

[Special For Computer room]

Rated capacity: 20KVA~60KVA


Scope Of Application

  • Computer Center
  • Computer room
  • Security monitoring host
  • Control Center
  • Highly stable power supply to protect equipment/environment
  • Model UPS FT-KP10K UPS FT-KP12K UPS FT-KP20K
    Single machine capacity 10KVA/12KVA/20KVA
    Full cabinet capacity 1+1 parallel: capacity 20KVA
    2+1 parallel: capacity 30KVA (one backup)
    1+1 parallel: capacity 24KVA
    2+1 parallel: capacity 36KVA (one backup)
    1+1 parallel: capacity 40KVA
    2+1 parallel: capacity 60KVA (one backup)
    Entire cabinet efficiency 89%, On-line online double conversion
    The structure and function of the whole cabinet The input, output and battery connection of the stand-alone machine and the cabinet are all designed with foolproof quick connectors
    The cabinet is a 19-inch rack-mounted design for the computer room, which can bear a load of about 1000 kg
    With thermal parallel function, each cabinet can backup each other, and at most eight cabinets can be connected in parallel.
    Inside the cabinet:
    It can accommodate three UPS single units in parallel, and the single unit adopts a rack-mounted design. It can also be equipped with four UPS stand-alone cabinets.
    Can hold hot-swappable battery modules
    Parallel switchboard with input/output terminal block
    Uninterrupted manual maintenance bypass switch
    Dual power input switch
    Equipped with input/output isolation module, it can solve the problem of poor grounding and leakage of the mains
    Optional output power distribution panel, including total output switch and 16P shunt switch (if stand-alone 20KVA does not support This feature)
    EPO emergency disconnect switch
    Enter Voltage and frequency 220V (single-phase two-wire), 220V or 380V (three-phase three-wire), 190/110V or 208/ 120V or 380/220V (three-phase four-wire), and can be specially designed according to requirements; +25% to -20%
    frequency and range 50Hz or 60Hz(automatic detection); ±4Hz
    Work factor improvement ≧ 0.99
    Harmonic Distortion (THDi) ≦6%
    output rated voltage and frequency 220/110V (single-phase three-wire); 50Hz or 60Hz
    stability rated voltage ± 1%; rated frequency ± 0.1Hz
    Waveform/Crest Ratio Pure sine wave/3:1
    Power factor 0.8
    Harmonic distortion (THDv) ≦3%@Under linear load; ≦10%@ under non-linear load
    Conversion time Zero conversion
    Battery
    Type Lead-acid water-free and maintenance-free closed type
    Discharge time Configure the battery pack according to customer needs to meet the discharge time
    Charging method Microcomputer controlled intelligent charging to extend battery life
    Replacement method The hot-swappable modular design is used for mutual backup. When replacing, it will not affect the normal operation of the UPS
    Protect With battery overcharge and discharge, battery overheating and battery short circuit protection
    Operation tips
    LED lights With mains normal, battery power supply, bypass output and UPS fault lights
    LCD panel With UPS input/output voltage, frequency information, battery capacity, load capacity, battery power supply 17 items such as time, abnormal state, silent start, mains input, bypass output, battery module, converter, ECO energy saving, programmable socket operation, load short circuit, output overload, battery failure and battery low potential
    Alarm sounds Battery discharge: beep every four seconds; battery low potential: beep every second ; Output overload: two beeps every second; UPS abnormal: long beep
    Single machine structure and function Special for computer room, 19-inch rack design
    Functions include: 1. Restore power after power failure, and automatically reboot
    2. It can be powered on by internal battery energy when there is no mains power
    3. The single machine has ECO energy-saving function, which increases the efficiency to 97%, which has achieved the purpose of energy-saving and power-saving
    4. Intelligently control the fan, according to the load and ambient temperature, automatically adjust the fan speed to reduce power consumption The purpose of noise
    5. Overload 101%~110% for 10 minutes; 111%~130% for 1 minute; 131% Switch to Bypass above. After the overload disappears, the system automatically switches back to the inverter power supply mode.
    6. Hot redundant parallel connection function, which can expand the load usage, and when two (above) machines are connected in parallel , Automatically share current output to the back-end load; as long as any UPS fails, the remaining normal hosts will automatically connect and supply all the loads, and the back-end equipment will not be interrupted. The connector adopts hot-swappable design, which can be repaired quickly without stopping the machine
    Communication interface
    standard configuration RS-232/USB/smart card slot
    Optional The smart card slot can be installed: RS-232/USB/SNMP/AS- 400/ModBus etc.
    Web/SNMP management interface SNMP network management card can be installed to remotely manage UPS
    Temperature detector Optional temperature detector, with expansion card slot for ambient temperature detection
    Monitoring software Support Win 2000/XP/Vista/7/8/10, Win Server 2003/2008/2012/2016 , Linux, Unix and Mac systems
    Safety certification With commodity verification registration certificate (BSMI), CNS14843-1( 1993 edition) and CNS14757-2 (99 edition)
    Noise (within one meter) ≦58dBA(Single machine)
    Use environment: temperature/humidity 0℃~40℃; 0%~90% (non-condensing)
    Size (mm)
    Length x Width x height
    Single machine 668x438x133 (3U) 696x438x266 (6U)
    Cabinet 944x571x1540 944x571x1880
    weight (kg)
    Single machine 22 24.5 46
    Cabinet 460 470 660

    *If there is any change to this product, a specification confirmation letter will be attached.
    *For more detailed information, please call to contact the specialist.