- UPS Uninterruptible Power System
- N+X Modular Uninterruptible Power System
- N+X Modular Compact UPS System
Features
Specification


| Model | UPS FT-EP12U | UPS FT-EP15U | |
|---|---|---|---|
| Single power module output capacity (W) | 20K or 30K | ||
| The efficiency of the whole machine | 94.5%, online double conversion design | ||
| Enter | Voltage | 415/240V or 400/230V or 380/220V (three-phase four-wire), also can be specially designed according to requirements | |
| Voltage range | 208V~478V @ <70% load; 305V~478V @ 100% load | ||
| Frequency | 50Hz or 60Hz (automatic detection) | ||
| Frequency range | 40Hz~70Hz | ||
| Work factor improvement | ≧0.99 | ||
| Harmonic Distortion (THDi) | ≦3% | ||
| output | Rated voltage | 415/240V or 400/230V or 380/220V (three-phase four-wire), also can be specially designed according to requirements | |
| Rated frequency | 50Hz or 60Hz | ||
| Stability | rated voltage ± 1%; rated frequency ± 0.1Hz | ||
| Waveform | Pure sine wave | ||
| Crest ratio | 3: 1 | ||
| Power factor | 1 | ||
| Harmonic distortion (THDv) | ≦2% @linear load; ≦4% @non-linear load | ||
| Conversion time | Zero conversion | ||
| Battery | |||
| Type | Lead-acid water-free and maintenance-free closed type | ||
| Battery pack | Working voltage is 240+240VDC | ||
| Discharge time | Configure the battery pack according to customer needs to meet the discharge time | ||
| Charging method | Microcomputer controlled intelligent charging to extend battery life | ||
| Protect | With battery overcharge and discharge, battery overheating and battery short circuit protection | ||
| Operation tips | |||
| LED lights | With mains normal, bypass power supply, UPS operation, battery supply and UPS failure lights | ||
| LCD panel | With UPS status and operation instructions, including input/output: voltage/current/frequency/actual power/apparent power/power factor , Load: capacity/percentage, battery: voltage/current/capacity and UPS fault display records (up to 500 records) | ||
| Alarm sounds | Battery discharge: one beep every two seconds; battery low: one beep every half second; output overload: one beep every second ; UPS abnormal: long beep | ||
| Display panel | The 5.7-inch LCD display panel makes it easier and faster to operate the UPS. | ||
| Panel monitoring | The LCD panel can record abnormal voltage/frequency and load warning range according to user settings. | ||
| Communication interface | |||
| Standard configuration | RS-232/ USB / smart card slot | ||
| Optional | The smart card slot can be installed: RS-232/USB/SNMP/AS-400/ModBus, etc. | ||
| Machine function | |||
| Modularization | Using modular design to achieve rapid detection and convenient replacement | ||
| shared battery pack | The shared design of the battery pack can ensure the average battery charge | ||
| Password maintenance management | To avoid operation by non-maintenance and management personnel, the LCD panel can set a password by itself. When the system is modified or the UPS is turned on, the correct password must be logged in to operate | ||
| N+X hot redundancy | Hot redundant parallel connection function, with future expansion capability, when the system is operating normally, each single power module will automatically share the current output For the back-end load; when any power module fails, the rest of the normal modules will automatically connect to supply all loads, and the power protection capability of the equipment will be increased to the highest point | ||
| Warning display | With buzzer sound and panel display dual prompt | ||
| Overload capacity | 101%~110% supply for one hour; 111%~125% supply for ten minutes; 126%~150% supply for one minute; > 151% provide 200ms and then switch to bypass. After the overload condition disappears, the system will automatically switch back to the inverter power supply mode. | ||
| Protection circuit | With output short-circuit, UPS leakage, input lightning surge protection, over-temperature protection and overload protection | ||
| ECO mode | Provide ECO power saving mode, increase performance to 98%, and achieve the purpose of energy saving and power saving | ||
| Other functions | With non-disruptive manual maintenance bypass function. No need to interrupt the backend load | ||
| Web/SNMP management interface | The SNMP network management card can be installed to remotely manage the UPS | ||
| Monitoring software | Support Win 2000/XP/Vista/7/8/10, Win Server 2003/2008/2012/2016, Linux, Unix and Mac systems | ||
| Safety certification | With the Commodity Verification Registration Certificate (BSMI) of the Bureau of Standards, Metrology, Inspection and Quarantine of the Ministry of Economic Affairs, CNS14843-1 (93 edition) and CNS14757-2(99 Year edition) | ||
| Noise (within one meter) | ≦70dBA | ||
| Use environment: temperature/humidity | 0℃~40℃; 0%~95% (non-condensing) | ||
| Dimensions, length x width x height (mm) | 1000 x 515 x 1285 | 1000 x 515 x 1420 | |
*If there is any change to this product, a specification confirmation letter will be attached.